CGQTF - INTERSHIELD PRORECO, PRA601

  • MSDS: CGQTF
  • Manufacturer: COURTAULDS COATINGS INC
  • Product Name: INTERSHIELD PRORECO, PRA601
  • National Stock Number: 8010-00N060114
Product Identification

Product ID:INTERSHIELD PRORECO, PRA601
MSDS Date:11/11/1996
FSC:8010
NIIN:00N060114
MSDS Number: CGQTF

Responsible Party
COURTAULDS COATINGS INC
6001 ANTOINE DR
HOUSTON, TX 77091
US

Emergency Phone: 800-854-6813;800-424-9300(CHEMTREC)

Info Phone: 713-684-1563

Cage: 50411

Contractor
INTERNATIONAL PAINT INC
HOUSTON, TX 77091 US

Telephone: 713-684-1244

Cage: 028S6

Ingredients

DIETHYLENETETRAMINE AND METHYL ISOBUTYL KETONE DIKETIMINE;

CAS: 10595-60-5

Fraction By Weight: 50-100%

OSHA PEL N/K

ACGIH TLV: N/K


2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (SARA

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: 1-10%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM;75 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


DIETHYLENETRIAMINE

CAS: 111-40-0

RTECS: IE1225000

Fraction By Weight: 1-10%

OSHA PEL 1 PPM

ACGIH TLV: 1 PPM, S

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION:VAPOR HARMFUL. MAY AFFECT
BRAIN OR NERVOUS SYSTEM CAUSING DIZZINESS, HEADACHE OR NAUSEA.
CAUSES NOSE AND THROAT IRRITATION. EYE/SKIN CONTACT:CAUSES BURNS.
THERE IS A RISK OF ABSORPTION THRO UGH UNBROKEN SKIN. INGESTION:MAY
BE FATAL IF SWALLOWED AND MAY CAUSE ORGAN DAMAGE. TOX INFO:THERE IS
NO(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:TOXICOLOGICAL DATA AVAILABLE ON
PRODUCT ITSELF. NOTICE:REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN AND NERVOUS SYSTEM DAMAGE. INT ENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING AND INHALING CONTENTS MAY BE HARMFUL OR
FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:IN ALL CASES OF DOUBT/WHEN SYMPS PERSIST, SEEK MED ATTN.
INHAL:REMOVE TO FRESH AIR. IF DISCOMFORT IS PRESENT/BRTHG IS ABSENT
GET MED ATTN IMMED. EYES:FLUSH IMMED W/PLENTY OF WATER FOR AT LST
15 MINS U NTIL IRRIT SUBSIDES. IF IRRIT PERSISTS,GET MED ATTN.
SKIN:FLUSH W/LG AMTS OF WATER. USE SOAP IF AVAIL. REMOVE SEVERELY
CONTAM CLTHG (INCL SHOES) & WASH BEFORE REUSE. IF IRRIT PERSISTS,
GET MED ATTN. I NGEST:DO NOT INDUCE VOMIT. KEEP AT REST. NEVER GIVE
ANYTHING BY MOUTH TO UNCON PERS. GET PROMPT MED ATTN.

Fire Fighting

Flash Point:104F,40C
Lower Limits:9999%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUST LIQ-CLASS II. ISOLATE FROM HEAT,
SPKS, ELEC EQUIP & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN EXPOS
TO EXTREME HEAT. IN ABSENCE OF ELEC, WATER SPRAY (FOG NOZZ IS PREF)
MAY BE USED TO COOL CNTNR S. DECOMP & COMBUST PRODS MAY BE TOX.

Accidental Release

Spill Release Procedures:CONTAIN SPILLED LIQ W/SAND OR EARTH. DO NOT
USE COMBUST MATLS SUCH AS SAWDUST. ABSORB SPILL W/INERT MATL (E.G.,
DRY SAND/EARTH), THEN PLACE IN CHEM WASTE CNTNR. CERCLA:MFR RECS
YOU CONT LOC AUTHS TO D ETERMINE IF THERE MAY BE OTHER LOC
REPORTING REQUIREMENTS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. LOOSEN CLOSURE
CAUTIOUSLY BEFORE OPENING. STORE IN A COOL, WELL VENTILATED PLACE
AWAY FROM INCOMPATIBLE MATERIALS.
Other Precautions:KEEP AWAY FROM HEAT, SPARKS & FLAMES. PROTECT MATL
FROM DIRECT SUNLIGHT. GROUND & BOND CONTAINERS WHEN TRANSFERRING
MATLS. EMPTY CONTAINERS MAY RETAIN HAZARDOUS PROPERTIES. FOLLOW ALL
MSDS/LABEL WARNI NGS, EVEN AFTER CONTAINER IS EMPTIED.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR I/A/W 29 CFR
1910.134 TO REMOVE PARTICULATES (AND VAPORS IF THERE IS
OVEREXPOSURE TO VAPORS GENERATED DURING PROCESSING OF THIS
PRODUCT).
Ventilation:PROVIDE SUFFICIENT VENT, IN VOL & PATTERN, TO KEEP TLV OF
HAZ INGS BELOW LIMS SPECIFIED & REMOVE VOLATILES PRDCD DURING CURE
& DECOMPOSITION PRODUCTS (SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES AND FULL LENGTH
FACESHIELD .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . CLOTHING AS NEEDED, USE BODY PROT TO AVOID CONTACT
W/PRODUCT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT: PRODUCED DURING WELDING OR CUTTING ON SURFACES COATED W/THIS
PRODUCT.

Chemical Properties

Boiling Pt:B.P. Text:9999F,5537C
Vapor Density:HVR/AIR
Spec Gravity:0.875
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS FUMES WHEN
HEATED TO DECOMP AS IN WELDING. FUMES MAY PRODUCE CARBON DIOXIDE &
CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.